Section VI. PREPARATION FOR STORAGE OR SHIPMENT
GENERAL
a. This section contains procedures for storing or shipping the aerosol generator.
b. Procedures dealing with overseas shipment are found in MIL-STD-162H.
c. Procedures dealing with administrative storage are covered in TM 740-90-1.
PREPARATION FOR STORAGE AND SHIPMENT
a. Inspections. Perform preventive maintenance checks and services in Chapter 4, Section III.
b. Repair. Repair or replace all damaged parts necessary.
BODY PREPARATION
a. Cleaning. Thoroughly wash all exterior parts of the aerosol generator. Use dry cleaning solvent P-D-680 to
break up grease and oil and liquid detergent, MIL-D-16791E to clean insecticide. Thoroughly flush the formulation tank,
the control panel nozzle assembly and fluid hoses. Use liquid detergent MIL-D-16791E. Drain oil from engine crankcase
and compressor crankcase. Remove rust and corrosion, and scrape any peeling paint.
b. Painting and Preserving. Dry all surfaces to be painted or coated with preservative. Repaint all surfaces as
necessary to protect against rust and corrosion.  Refer to TM 43-0139.  Cover all exposed metal surfaces with
preservative oil MIL-C-8188.
5-263/5-264 (Blank)