Figure 5-275. Control Panel Assembly
FORMULATION TANK ASSEMBLY MAINTENANCE (Continued)

TM-5-3740-214-14 Aerosol Generator Non-Thermal Insecticide Unltra-Low Volume Model XKA (NSN 374001-076-1341) Manual
Page Navigation
  396    397    398    399    400  401  402    403    404    405    406  
TM 5-3740-214-14
FORMULATION TANK ASSEMBLY MAINTENANCE
Figure 5-277. Formulation Tank
a. Remove formulation tank assembly.
WARNING
BE SURE there is no pressure on the formulation tank before removing it.
BE SURE the formulation tank is empty before removing it.
BE ALERT not to spill insecticide on skin or clothing when removing the hoses.
(1) Drain formulation tank.
(2) Open air pressure drain valve.
(3) Remove spring and valve guard bracket.
(4) Remove tank fluid drain valve assembly.
(5) Disconnect fluid hoses from three-way valve, junction block, and regulator.
Figure 5-278. Formulation Tank Fluid Drain Valve