Table 5-3. Direct and General Support Maintenance Troubleshooting (Continued) -502230234
Table 5-3. Direct and General Support Maintenance Troubleshooting (Continued) -502230236

TM-5-3740-214-14 Aerosol Generator Non-Thermal Insecticide Unltra-Low Volume Model XKA (NSN 374001-076-1341) Manual
Page Navigation
  224    225    226    227    228  229  230    231    232    233    234  
TM 5-3740-214-14
Table 5-3. Direct and General Support Maintenance Troubleshooting (Continued)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
THE ENGINE IS HARD TO START (Continued)
Figure 5-83. Ignition Wire Test
(2)
Connect a meter lead to each end of the wire and check the continuity.
(3)
Remove the breaker point wire from the points and the coil.
(4)
Connect a meter lead to each end of the wire and check for continuity.
(5)
Wiggle the wire back and forth. If the meter does not register a current, replace it and go to Step
4e. If the meter does register a current, go to Step 5.
f.
Start the engine.
(1)
If the engine starts without trouble, the problem is solved.
(2)
If the engine does not start, or if it is hard to start, go to Step 5.
Step 5.
Check the breaker points.
5-76