• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Pan Assembly Replacement.
Pan Assembly Replacement Continued.

TM-10-5410-228-24 Chemical Biologiocal Protective Shelter (CBPS) System NSN 5410-01-441-8054 (Green) (EIC:5ZT) NSN 5410-01-482-4633 (Tan) Manual
Page Navigation
  286    287    288    289    290  291  292    293    294    295    296  
TM 10-5410-228-24
2.13.25 Pan Assembly Replacement Continued.
(3)
Remove nuts (20), lockwashers (21), and washers (22) securing terminal lugs (23) and wires to
relay (24). Tag and remove wires.
(4)
Remove four screws (25), four lockwashers (26) and four flat washers (27) securing relay (24) to
mounting pan (1) and remove relay (24). Discard four lockwashers (26).
(5)
Remove nut (28), lockwasher (29), flat washers (30 and 31), nut (32), lockwasher (33) and flat
washer (34) from ground stud (10). Remove ground stud (10) from mounting pan (1). Discard
lockwashers (29 and 33).
(6)
Remove two screws (35), two lockwashers (36) and two flat washers (37) securing bracket (38).
Remove bracket (38). Discard two lockwashers (36).
(7)
Remove relay (39) from socket (40).
(8)
Tag and remove wires from socket (40).
(9)
Remove two screws (41), two lockwashers (42) and two flat washers (43) securing socket (40) to
mounting pan (1). Discard two lockwashers (42).
(10) Remove relay (44) from socket (45).
(11) Tag and remove wires from socket (45).
(12) Remove two screws (46), two lockwashers (47) and two flat washers (48) securing socket (45) to
mounting pan (1). Discard two lockwashers (47).
(13) Remove relay (49) from socket (50).
(14) Tag and remove wires from socket (50).
(15) Remove two screws (51), two lockwashers (52) and two flat washers (53) securing socket (50) to
mounting pan (1). Discard two lockwashers (52).
(16) Remove relay (54) from socket (55).
(17) Tag and remove wires from socket (55).
(18) Remove two screws (56), two lockwashers (57) and two flat washers (58) from socket (55).
Discard two lockwashers (57).
(19) Remove four barbed connectors (59) on inside of mounting pan (1) from four barbed connectors
(60) on back of mounting pan (1).
(20) Tag and remove wires from neutral and ground bars (61).
(21) Remove two nuts (62), two lockwashers (63), two flat washers (64) and two screws (65) securing
neutral and ground bars (61) to mounting pan (1). Remove neutral and ground bars (61).
Discard two lockwashers (63).
NOTE
Note polarity on diodes before removing (Refer to Figure 2-46, sheet 5, View B-B).
(22) Remove four diodes (66) from terminal board TB2 (67). Tag and remove wires from terminal
board TB2 (67).
(23) Remove two nuts (68) and two screws (69) securing terminal board TB2 (67) to mounting pan (1)
and remove terminal board TB2 (67).
NOTE
Note polarity on diodes before removing (Refer to Figure 2-46, sheet 5, View C-C).
(24) Remove eight diodes (70) from terminal board TB1 (71). Tag and remove wires from terminal
board (71).
(25) Remove two nuts (72) and two screws (73) securing terminal board TB1 (71) to mounting pan (1)
and remove terminal board TB1 (71).
2-228