NO POWER TO SYSTEM WITH `EXT' POWER APPLIED Continued. -812530143
SWITCH/INDICATOR DIM.

TM-10-5410-228-24 Chemical Biologiocal Protective Shelter (CBPS) System NSN 5410-01-441-8054 (Green) (EIC:5ZT) NSN 5410-01-482-4633 (Tan) Manual
Page Navigation
  116    117    118    119    120  121  122    123    124    125    126  
TM 10-5410-228-24
2.8
UNIT LEVEL TROUBLESHOOTING PROCEDURES Continued.
15. CONVERTER INDICATOR LIGHTS ON.
Converter EXTENDED INPUT RANGE indicator.
Test 10 kW TQG
output.
No
Is 10 kW TQG
Adjust or repair per
output normal?
TM 9-6115-642-10.
Yes
Replace converter
(see para 2.13.20).
Converter OVERLOAD indicator.
Test 10 kW TQG
output.
Adjust or repair per
No
10 kW TQG
TM 9-6115-642-10.
output normal?
Yes
Does load
No
Replace converter.
exceed 75 amps
(2 kW)?
Yes
Do continuity check of electrical wiring
from 1A4J7-A to 1A4S1-A3, 1A4J7-B to
1A4S1-A7 & 1A4J7-C to 1A4S1-A11
per Appendix F, Fig. F-9, sheet 1.
Repair wiring as required.
2-58