TM 10-5410-228-24
2.8
UNIT LEVEL TROUBLESHOOTING PROCEDURES Continued.
4.3 ERRATIC GOVERNOR OPERATION
Measure DC voltage at terminasls 1
& 2 on EPG control unit.
Should read normal battery voltage.
Yes
Voltage normal?
Wiring is correct.
No
Low battery voltage. (Voltage
20% below rated or lower?)
Yes
Check battery and
Voltage low?
charging system.
No
RFI noise due to poor connections
or damage shielding on wires.
No
Connections and/or
Repair as required.
shielding OK?
2-24