• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 1-7. Recirculation Filter -812530041
Section III. PRINCIPLES OF OPERATION -812530043

TM-10-5410-228-24 Chemical Biologiocal Protective Shelter (CBPS) System NSN 5410-01-441-8054 (Green) (EIC:5ZT) NSN 5410-01-482-4633 (Tan) Manual
Page Navigation
  17    18    19    20    21  22  23    24    25    26    27  
TM 10-5410-228-24
1.13 EQUIPMENT DATA.
CBPS (includes crew gear, medical equipment and pintle weight)
(ECV total load includes crew, fighting gear, and pintle weight)
CBPS Total Weight:
15,700 lb
Curb Weight:
6,100 lb
Gross Weight:
11,500 lb
Payload:
5,098 lb
Front Axle:
5,750 lb
Rear Axle:
7,000 lb
ECV Total Load:
11,500 lb
HMT:
4,200 lb
Static Profile
Mobile Profile
Length:
328 in.
Length: 516 in.
Width:
87 in.
Width:  226 in.
Height:
103.5 in.
Height:  126.5 in.
Bridge Class (MLC):
Empty: 2
Loaded: 4
Axle Weight Rating:
Front: 5,750 lb
Rear: 7,000 lb
Ground Clearance:
16.5 in.
Fording Depth:
60 in.
Max Grade:
1
22
Max Side Slope:
V7
Center of Gravity:
Vehicle:
ertical: 42.3 in. above ground
Longitudinal: 51.6 in. forward of rear axle C/L
Latitudinal: 0.85 in. right of C/L
Vertical: 37.5 in. above ground
HMT:
Longitudinal: 6.5 in. forward of axle C/L
Latitudinal: On HMT longitudinal C/L
Fuel Economy:
8 hrs per tank (estimated)
Range:
275 mi. (approximately)
INVERTER
Input Voltage:
28 Vdc (22 Vdc to 29 Vdc)
Extended Range:
18 Vdc to 32 Vdc
Output Voltage:
120 Vac (117.6 Vac to 122.4 Vac)
Output Current:
11.6 amps at 120 Vac
Output Frequency:
60 Hz2%
Output Power:
1.4 kW
Weight:
32 lb (approx.)
CONVERTER
Input Voltage:
208 Vac (197 Vac to 208 Vac)
Extended Range:
188 Vac to 225 Vac
Input Phase:
3 phase/4 wire
Input Frequency:
47 Hz to 63 Hz
Output Voltage:
Range 26.6 Vdc to 29.4 Vdc (28 Vdc Nominal)
Output Power:
2 kW
Weight:
25 lb (approx.)