TM 5-6350-264-14&P-9
NAVELEX EE 181-AA-OMI-100/E121 DZ-204
T.O
31S9-2FSS9-1-9
NOTE
Troubleshooting procedures listed in table 5-1 may require more than one person to perform corrective
action.
Covers should be removed as necessary to perform troubleshooting procedures.
Never disconnect a wire without first marking that wire to assure proper reconnection.
Table 5-1 Troubleshooting Procedures
Trouble
Probable cause
Corrective action
1
Constant
a
Poor or broken
a
Set multimeter to dc volts
Connect positive meter
alarm.
ground con-
lead to TB2-1 and negative meter lead to TB2-2.
nectors
Meter should indicate more than 1 vdc.
(1) If meter does not indicate more than 1 vdc
for both tests, turn power switch S3 to
POWER OFF.
(2) Set multimeter to ohms Connect leads to
TB2-1 and TB2-2, and then to TB2-2 and
TB2-3 Meter should indicate 100, 000
ohms or more for both tests.
(3) If the meter indicates less than 100, 000 ohms,
inspect wiring and P1 for shorts, broken
or loose connections, or bent pins.
b
Connect meter leads to the following points:
TB2-1 to P1-25;
TB2-3 to P1-13;
TB2-2 to outer enclosure;
TB2-2 to P1-3, 4, 16, 17;
TB2-2 to P1-23;
TB2-2 to battery negative lead;
TB2-2 to TB3-3.
Meter should indicate 0 ohms at each point.
c
If the multimeter reads more than 0 ohms at any of
the above points, inspect wiring for broken or loose
connections, inspect plugs for bent or broken pins
and inspect conduit for poor connections. Repair
or replace defective wiring or connectors.
5-6