TM 5-6350-264-14&P-10
NAVELEX EE 181-AA-OMI-11A/E121 C-9412
T.O. 31S9-2FSS9-1-10
CHAPTER 1
INTRODUCTION
Section I. GENERAL
1-1. SCOPE. This manual is for your use in operating
and maintaining the Alarm Set, Control Unit Model C-
9412/FSS-9(V), under normal operating conditions. The
Control Unit (CU) is an integral part of the Joint-Services
Interior Intrusion Detection System (J-SIIDS). For
information on other major assemblies of J-SIIDS, refer
to the applicable manual listed in appendix A..
1-2. MAINTENANCE FORMS AND RECORDS.
Equipment maintenance forms and procedures for their
use are contained in DA PAM 738-750, The Army
Maintenance Management System (TAMMS).
1-3. ADMINISTRATIVE STORAGE. Instructions for
administrative storage are contained in TM 740-90-1.
1-4. DESTRUCTION OF ARMY MATERIEL TO
PREVENT ENEMY USE. Instructions for the destruction
of Army materiel to prevent enemy use are contained in
TM 750-244-3.
1-5. QUALITY ASSURANCE/QUALITY CONTROL.
There are no Quality Assurance/Quality Control technical
manuals applicable to this equipment.
1-6. REPORTING EQUIPMENT IMPROVEMENT
RECOMMENDATIONS (EIR). EIRs will be prepared on
standard
Form
368,
Quality
Deficiency
Report.
Instructions for preparing EIRs are provided in DA PAM
738-750. EIRs should be mailed directly to Commander,
U. S. Army Troop Support Comamnd, ATTN: AMSTR-
QX, 4300 Goodfellow Blvd. , St. Louis, Missouri 63120-
1798. A reply will be furnished directly to you.
Section II. DESCRIPTION AND DATA
1-7. DESCRIPTION. The Control Unit (fig. 1-1 and 1-2)
consists of a steel enclosure, a power supply, a battery
for emergency operation, a status processor, associated
controls,
and
input/output
terminal
boards.
The
enclosure also contains mounting provisions for the Data
Transmitter T-1257/FSS-9(V) (not part of the Control
Unit). The Control Unit is the central control element of
J-SIIDS. A tamper alarm switch (TAS) automatically
initiates an alarm when the access door is opened.
1-8. TABULATED DATA.
a. Identification Data. There are three identification
plates on the Control Unit as follows: One located inside
the access door (fig. 1-3, view a); one located on
top of the power supply (fig. 1-3, view b); one located on
the bottom of the status processor (fig. 1-3, view c).
b. Equipment Characteristics.
Weight (Control Unit less battery and
Data Transmitter .............. 38 pounds (17.24 kg)
Dimensions (overall)
Height............................... 22.500 inches (57.5 cm)
Width................................ 8.250 inches (21.0 cm)
Depth ............................... 14.625 inches (37.0 cm)
Change 1 1-1