5-9.
SECONDARY HYDRAULIC MANIFOLD ASSEMBLY REPAIR
This task covers:
Disassembly
Cleaning
Solenoid
Repair
Flow
Regulator
Repair
Assembly
A.
INITIAL SETUP
Tools and Special Equipment:
General Safety Instructions:
Tool Kit, 5180-00-177-7033
Materials/Parts:
WARNING
O-Ring
Appendix E, Item 41
Death or serious injury could result
by repeated and/or prolonged
Kit, Parts Repair
Appendix E, Item 29
breathing and/or skin contact of
drycleaning solvent (P-D-680). Use in
Kit, Parts Repair
Appendix E, Item 28
a well-ventilated area. Do not use
near open flame or in excessive heat.
Solvent, Drycleaning,
Appendix E, Item 59
The flash point of this solvent is
P-D-680
100°F-183°F (38°C-59°C).
Sealant, Thread
Appendix E, Item 55
Compressed air used for cleaning and
drying purposes shall not exceed 30
Equipment Condition:
psi. Use only with effective chip
guarding and personal protective
Reference
Condition Description
equipment (goggles/shield, gloves,
etc.). Flying debris could cause
Paragraph 4-32
Secondary Hydraulic
personal injury debris could cause
Manifold Removed
5-22