PRIMARY HYDRAULIC MANIFOLD ASSEMBLY REPAIR - Continued
HAND CONTROL ASSEMBLY REPAIR

Operator Manual Pesticide Dispersal Unit, Multicapability, Helicopter Slung
Page Navigation
  259    260    261    262    263  264  265    266    267    268    269  
img
.
TM 5-3740-218-13&P
PRIMARY HYDRAULIC MANIFOLD ASSEMBLY REPAIR (CONT)
H.
ASSEMBLY
(1)
Install flow regulator (1).
(2)
Install needle valve (2).
(3)
Install relief valve (3).
(4)
Install solenoid (4).
(4)
Install solenoid coil (5) and secure with nut (6).
(5)
Install new O-ring (7).
(6)
Apply thread sealant (item 55, Appendix E) to pressue gage threads and install pressure gage (8). Wipe off
r
excess sealant.
5-32