PUMP AND CROSSTUBE ASSEMBLY HYDRAULIC MOTOR REPLACEMENT
PUMP AND CROSSTUBE ASSEMBLY SPRAY SYSTEM CONTROL REPLACEMENT

Operator Manual Pesticide Dispersal Unit, Multicapability, Helicopter Slung
Page Navigation
  186    187    188    189    190  191  192    193    194    195    196  
img
TM 5-3740-218-13&P
C.
ASSEMBLY
NOTE
When assembling pump and motor, low-pressure outlet must be on same side as
pump outlet.
(1)
Align key on motor shaft with keyway of new pump.
(2)
Slide shaft of new motor (1) into pump (2).
(3)
Install two bolts (3) through bolt holes on motor (1) and pump (2).
(4)
Install pump mounting brace (4) over ends of two bolts (3).
(5)
Install two washers (5) and secure with two nuts (6).