PUMP AND CROSSTUBE ASSEMBLY REPLACEMENT
C.
INSTALLATION
(1)
Using two persons, support pump and crosstube assembly (1) from underneath and install pump and
crosstube assembly (1) under bucket downspouts.
(2)
Loosen clamp on main crosstube weldment to allow for adjustment. Position vertical weldments under
downspouts, aligning mounting holes.
(3)
Install two suitable clamps on each side of downspouts to hold weldments in position.
(4)
Adjust weldments as required to obtain tight fit and install 40 flat washers (2), 20 bolts (3), 20 locknuts (4),
and 20 clips (5). Install pump strut (6) on right side downspout.
(5)
Connect level switch wiring harness (7) to bucket harness.
(6)
Connect quick-disconnect fitting (8) at primary manifold.
(7)
Connect quick-disconnect hydraulic fitting (9) to hydraulic filter.
(8)
Connect two quick-disconnect hydraulic fittings (10 an 11) from spray control assembly to rear of
d
secondary manifold, matching marks on connectors with marks on secondary manifold.
(9)
Close ball valve (12) and gate valve (13).
(10)
Install strainer (14).
4-104