TM 5-3740-218-13&P
Table 2-4. Operator Level PMCS (Cont)
NOTE: Within designated interval, these checks are to be performed in the order listed.
B-Before
D-During
A-After
EQUIPMENT IS NOT
Item To Be
Procedures
ITEM
INTERVAL
READY/AVAILABLE IF:
Inspected
NO.
B
D
A
WARNING
Battery electrolyte is an
acid, and is highly corrosive.
Wear rubber gloves, face
shield, and apron. Do not
spill on clothing, skin, or
PDU. Wash exposed areas
with water. Seek medical
assistance. Failure to do so
could result in personal
injury.
4
Battery
Check terminals for corrosion.
Terminals corroded or
Check battery for cracks and
cables loose. Battery
leaks. Ensure cables are tight.
cracked or leaking.
Check battery box for damage.
Refer to unit maintenance.
5
Air Cleaner
Check for cleanliness; clean if
Clogged or damaged.
dirty.
NOTE
Ensure 3/4-in. ball valve is
closed before filling bucket.
6
Bucket
Check for cracks. If liquid
Leaks exceed Class II.
pesticide will be dispersed, fill
with water to 30-gal mark (leave
water in bucket for use in other
checks).
Doors,
Check for ease of operation and
Cannot be secured.
Gaskets,
proper seal.
and Ports
Fin
Check to see if loose or broken.
Not secured, broken,
or missing.
Frame
Check for loose, broken, or
Components loose,
missing hardware.
broken, or missing.
2-10