EXPLANATION OF COLUMNS IN THE TOOLS AND TEST EQUIPMENT REQUIREMENTS, SECTION III
SECTION III. MAINTENANCE ALLOCATION CHART FOR CARBON DIOXIDE RECHARGING UNIT

Recharging Unit, Carbon Dioxide Reciprocating Pump, Electric Motor Driven, Ac, 115Volt Single Phase, 60 Hz, 1Hp, 12681, 12681-2
Page Navigation
  85    86    87    88    89  90  91    92    93    94    95  
img
TM 5-3655-214-13&P
SECTION II. MAINTENANCE ALLOCATION CHART
FOR
CARBON DIOXIDE RECHARGING UNIT
(1)
(5)
(2)
(3)
(6)
(4)
GROUP
TOOLS AND
COMPONENT/
MAINTENANCE
REMARKS
MAINTENANCE LEVEL
NUMBER
EQUIPMENT
ASSEMBLY
FUNCTION
CODE
REFERENCE
CODE
FIELD
SUSTAINMENT
DIRECT  GENERAL
UNIT
DEPOT
SUPPORT SUPPORT
C
O
F
H
D
01
SUPPORTS
Replace
0.5
1
02
GUARDS
Replace
0.3
1
03
BELT AND
Inspect
0.1
PULLEY
Adjust
0.3
1
BELT
Replace
0.5
1
PULLEY
Replace
0.4
1
04
ELECTRIC
Inspect
0.1
MOTOR
Test
0.1
3
MOTOR
Service
0.1
ASSEMBLY
Replace
0.6
1
Repair
3.0
1
CAPACITOR
Test
0.1
Replace
0.3
2
05
LINES AND
Inspect
0.1
FITTINGS
Replace
0.2
1
HOSE
ASSEMBLIES
VALVES,LINES
Inspect
0.2
AND FITTINGS
Replace
0.5
1
06
PUMP
Service
0.1
PUMP ASSEMBLY
Repair
1.0
1
07
STARTER AND
Test
0.1
3
CABLES
Replace
0.5
1
STARTER
Power Cable
0.5
1
Repair
1.0
1
1
WIRING
Replace
0.5
1
HARNESS
Repair
1.0
5.0
1
08
SKID
Replace
B-5
Change 1