TX 3-6665-316-12
2-5.
ASSEMBLY AND PREPARATION FOR USE (continued)
25.
Locate coaxial connector (14) on one face of receiver ring.
26.
Remove antenna from transit case.
Aline slots (15) on antenna jack
with studs (16) on coaxial connector.
27.
Push antenna jack down onto coaxial connector and, at same time, turn
antenna jack clockwise 1/4 turn to lock.
28.
29.
3
0.
31.
32.
33 l
2-14
P16
r
If detector is to be powered by BA3517/U Batteryy perform Steps 29
and 30.
If detector is to be powered by source other than BA3517/U
Battery, go to Step 31.
Notify personnel within audible range thatan alarm may sound.
Push
extender cable connector onto M43A1 Detector 24 VDC INPUT connector
and then turn connector 1/4 turn clockwise to lock.
Go to Step 32.
To connect power source
other than BA3517/U Battery, notify person-
nel within audible range that an alarm may sound.
Push power source
connector onto M43A1 Detector 24 VDC INPUT connector and then turn
power source connector lockring 1/4 turn clockwise to lock.
If alarm sounds when power is connected , allow the alarm to sound at
least five times. Then press BATTERY TEST AND RESET PRESS button.
The BATTERY TEST AND RESET PRESS button may have to be held down for
60 seconds.
The above procedure may have to be repeated several
times.
Repeat the above steps for each receiver.