Figure D-67. Electrical wireC5-45-3248-15.
Figure D-69. Electrical wire C5-45-3248-17.

Technical Manual For Decontaminating Apparatus: Power-Driven, Skid-Mounted, 500-Gallon, M12A1
Page Navigation
  479    480    481    482    483  484  485    486    487    488    489  
img
TM 3-4230-209-30&P
D-40
MATERIAL
PART NO.
DESCRIPTION
QTY
MM2946
WIRE, ELECTRICAL
1
MS25036-8
LUG, TERMINAL
2
1. CUT BULK ELECTRICAL WIRE 12.50 INCHES LONG.
2. STRIP 0.375 INCH INSULATION FROM EACH END AND CRIMP
TERMINAL LUG ON EACH END.
3. ALL DIMENSIONS ARE IN INCHES.
Figure D-68. Electrical wire C5-45-3248-16.