LIQUID FUEL WATER HEATER AND CABINET TOP COVER. - Continued
LIQUID FUEL WATER HEATER AND CABINET TOP COVER. - Continued

Technical Manual For Decontaminating Apparatus: Power-Driven, Skid-Mounted, 500-Gallon, M12A1
Page Navigation
  154    155    156    157    158  159  160    161    162    163    164  
img
Machine screw (52)
Remove one machine screw (52), internal troth lock washer (53), and
Internal tooth lock
loop clamp (54) securing wire bundle to top inboard corner of the control
washer (53)
box (55). Carefully slip loop clamp (54) from wire bundle and capillary
Loop clamp (54)
tubes. Repeat for lower loop clamp holding wires running downward from
Control box (55)
control box.
Electrical splice (56)
Cut two electrical splices (56) for the electrical wires to thermostatic
Thermostatic switch (57)
switch (57). Remove thermostatic switch (57).