CENTRIFUGAL PUMP. - Continued
CENTRIFUGAL PUMP. - Continued

Technical Manual For Decontaminating Apparatus: Power-Driven, Skid-Mounted, 500-Gallon, M12A1
Page Navigation
  103    104    105    106    107  108  109    110    111    112    113  
img
. . .
2-102
TM 3-4230-209-30&P
2-22. CENTRIFUGAL PUMP (CONT).
LOCATION/lTEM
ACTION
REMARKS
Centrifugal Pump/
Use a drill to enlarge the existing unthreaded holes to 13/64 inch diame-
ter. Tap the two holes 1/4-20 UNC through the pump impeller at the
location shown.
Remove cotter pin (11), castellated plain nut (12), and flat washer (13).
Cotter pin (11)
Castellated plain nut (12)
Flat washer (13)
Using a fabricated wheel puller (fig D-3) (14), screw two 1-1/4 inch long
Always use a wheel puller (see figure D-3) to remove
Wheel puller (14)
screws (fig D-3) (15) into the two tapped holes in pump impeller (16).
the impeller from the pump shaft. Removal of the
Alternately tighten the screws in the holes until pump impeller (16) is
Screws (15)
pump impeller by the procedure described below will
Pump impeller (16)
released. Slide pump impeller (16) off the shaft (17). Unscrew and remove
prevent damage to the pump shaft seal assembly.
the two screws (15) and wheel puller (14).
Shaft (17)