TROUBLESHOOTING - Continued
WATER HEATER - Continued

Technical Manual For Decontaminating Apparatus: Power-Driven, Skid-Mounted, 500-Gallon, M12A1
Page Navigation
  6    7    8    9    10  11  12    13    14    15    16  
img
. . .
WATER HEATER
1. WATER HEATER DOES NOT HEAT WATER
Step 1. 24 vdc is not available from pump unit.
Troubleshoot pump unit. See malfunction 5,
page 2-4.
Step 2. Check for defective thermostatic switch S1
using the following procedures:
a. Remove TD2 tube from its socket.
b. Use multimeter to measure continuity.
Check from TD2 socket, hole 7, to switch
S4-1. If continuity is not indicated, thermo-
static switch S1 in top of the boiler is bad.
Reinstall TD2 tube (para 2-33).
Replace thermostatic switch S1 (para 2-33).
2-5
TM 3-4230-209-30&P