T.O. 33B-1-12-72Table 2-5. Developer Forms and Application Methods in Decreasing Order of Sensitivity.Developer Form Application Method1.Non-aqueous wet (solvent suspended) Spray2.Water suspended Spray3.Water suspended Immersion4.Water soluble Spray5.Water soluble Immersion6.Dry powder Dip and pour7.Dry powder Electrostatic spray8.Dry powder Fluidized bed9.Dry powder Air agitated dust cloudFigure 2-25. Comparison of Four Forms of Developer on a Cracked Chrome Plated Panels.