TM 5-6350-264-14&P-10NAVELEX EE 181-AA-OMI-110/E121 C-9412T.O. 31S9-2FSS9-1-10Table 5-2. Troubleshooting Procedures - ContinuedTroubleProbable causeCorrective action2. (Cont)f.(Cont)a soldering iron of 50 watts maxi-mum to remove wires from switchterminals.(2)To install new TRANSMITTER RE-SYNC switch, use a soldering ironof 50 watts maximum to solderwires to switch terminals. Insertswitch through hole in panel fromrear. Place hex nut over threadedportion of switch and tighten tosecure.f.If meter indicates 0 ohms with switch de-pressed, connect leads to TB7, terminalS-7 and to switch terminal with redwire attached. Meter should indicate0 ohms.g.If meter indicates more than 100, 000 ohms,inspect wires from TB7, terminal S-7to J12/P1, pin 23, and from J12/P1,pin 23 to switch (red wire) for brokenor loose connections. Resolder any badconnections on P1.h.If meter indicates 0 ohms, connect leads toother switch terminal (black wire) andpower supply TB2-4. Meter should in-dicate 0 ohms.i.If meter indicates more than 100, 000 ohms,inspect wires from switch to J12/P1,pin 34, and from J12/P1, pin 34 topower supply TB2-4 for broken orloose connections. Resolder any looseconnections on P1.j.Reconnect Data Transmitter wire to TB7,terminal S-7.k.Turn on switch S1 on power supply. De-press TRANSMITTER RESYNCswitch S2. Wait about 5 minutesfor system to stabilize. Turn modeswitch to TEST/RESET and then toSECURE.5-51