Troubleshooting Procedures - Continued - TM-5-6350-264-14P-10_128
Troubleshooting Procedures - Continued - TM-5-6350-264-14P-10_130

TM-5-6350-264-14P-10 Alarm Set Control Manual
Page Navigation
  114    115    116    117    118  119  120    121    122    123    124  
TM 5-6350-264-14&P-10 NAVELEX EE 181-AA-OMI-110/E121 C-9412 T.O. 31S9-2FSS9-1-10 Table 5-2.  Troubleshooting Procedures - Continued Trouble Probable cause Corrective action 8. (Cont) Bad alarm (3)   Turn on switch S1 on power sup- identification ply.  Depress TRANSMITTER circuitry. RESYNC switch 2.  Wait (Cont) about 5 minutes for system to stabilize.  Turn mode switch to TEST/RESET and then to SECURE. p. Turn mode switch to ACCESS.  If meter indicates 0 volts at S3, terminal 2-3, connect positive meter lead to wire removed from terminal 2-3.  If meter indicates 20 ±1 vdc on wire, replace status processor. (1)   To remove status processor, turn off switch S1 on power supply. Tag and disconnect Data Trans- mitter wires from TB6 and TB7. Remove screws that secure Transmitter to standoffs in CU. Be careful not to drop Trans- mitter inside CU.  Remove Data Transmitter.  Loosen screws that secure plug P1 to bottom of status processor. Pull plug P1 straight down to disconnect it.  Remove screws that secure status processor to top of CU enclosure and it will drop straight down. (2)   To install new status processor, position it under standoffs in top of CU.  Insert four screws and tighten to secure status processor.  Insert plug P1 into connector on bottom of pro- cessor, and push up.  Tighten screws to secure plug P1. Position Data Transmitter over standoffs in CU and insert screws.  Tighten screws to se- cure Transmitter.  Connect wires to TB6 and TB7 in CU. 5-111







Western Governors University

Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved. Design by Strategico.