ULV BOOM ASSEMBLY REPAIR - Continued
ROTARY ATOMIZER ASSEMBLY REPAIR

Operator Manual Pesticide Dispersal Unit, Multicapability, Helicopter Slung
Page Navigation
  202    203    204    205    206  207  208    209    210    211    212  
img
TM 5-3740-218-13&P
ULV BOOM ASSEMBLY REPAIR (CONT)
C.
ASSEMBLY
(1)
Align two quick-release pins (1) and two cable assemblies (2) on boom (3) and secure with two screws (4).
(2)
Install two dust caps (5) and two hydraulic couplers (6) on ends of hydraulic hoses (7 and 8).
(3)
Install two rotary atomizer assemblies (9) and four clamps (10) on boom (3).
(4)
Install two adapters (11), two hex nipples (12), two orifice discs (13), and two tee-jet diaphragms (14) at top
of each rotary atomizer assembly (9).
(5)
Install two fittings (15) at one end of two push-on hoses (16).
(6)
Lubricate two push-on hoses (16) with soap and water. Push through boom (3).
(7)
Install two clamps (17) and two cap assemblies (18) on two push-on hoses (16).
(8)
Connect two push-on hoses (16) to two tee-jet diaphragms (1 ).
4
(9)
Connect hydraulic hoses (7 and 8) to two rotary atomizer assemblies (9).