C.
CLEANING
(1)
Use general cleaning methods to clean all parts (para 1-15) except filter element.
WARNING
Do not use gasoline or low flashpoint solvent for cleaning. Both are flammable
and explosive under certain conditions. Serious personal injury could result if fuel
ignites.
Death or serious injury could result by repeated and/or prolonged breathing and/or
skin contact of drycleaning solvent (P-D-680). Use in a well-ventilated area. Do
not use near open flame or in excessive heat. The flash point
of this solvent is 100°F-183°F (38°C-59°C).
(2)
Wash filter element in high flashpoint solvent (item 60, Appendix E) and dry.
(3)
Dip filter element in clean engine oil (item 36, Appendix E) and squeeze out excess oil.
D.
ASSEMBLY/INSTALLATION
(1)
Place air cleaner case (1) in position on air cleaner stay (2).
(2)
Install two nuts (3) on carburetor mounting studs.
(3)
Secure air cleaner case (1) to stay (2) using nut (4).
(3)
Install breather tube (5).
(4)
Install new drain tube filter (6).
(5)
Install new seal (7) and separator (8) on air cleaner case (1) and secure using six nuts (9).
(6)
Place air cleaner element (10) in separator (8).
(7)
Place air cleaner cover (11) on separator (8) and secure with top and bottom clips (12).