Table 5-3. Direct and General Support Maintenance Troubleshooting (Continued) -502230338
Table 5-3. Direct and General Support Maintenance Troubleshooting (Continued) -502230340

TM-5-3740-214-14 Aerosol Generator Non-Thermal Insecticide Unltra-Low Volume Model XKA (NSN 374001-076-1341) Manual
Page Navigation
  328    329    330    331    332  333  334    335    336    337    338  
TM 5-3740-214-14
Table 5-3. Direct and General Support Maintenance Troubleshooting (Continued)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
NOZZLE PRESSURE GREATER THAN 100 PSI (Continued)
Figure 5-197. Separator Assembly
b.
Inspect the filter element.
(1)
If the filter element is plugged, clean it with acetone (O-A-51F), replace it and go to Step 1c.
(2)
If the filter element is ok, go to Step 1c.
c.
Inspect the gaskets.
(1)
If the gasket is cracked or broken, replace it and go to Step 1d.
(2)
If the gasket is ok, go to Step 1d.
d.
Reassemble the separator and start the engine. Check the pressure gage.
(1)
If the pressure is 90-100 psi, the problem is solved.
(2)
If the pressure is still greater than 100 psi, go to Step 2.
Step 2.
Check the engine speed. Use a hand-held tachometer.
a.
Start the engine according to operating instructions in Chapter 2, Section III.