Table 5-3. Direct and General Support Maintenance Troubleshooting (Continued) -502230325
Table 5-3. Direct and General Support Maintenance Troubleshooting (Continued) -502230327

TM-5-3740-214-14 Aerosol Generator Non-Thermal Insecticide Unltra-Low Volume Model XKA (NSN 374001-076-1341) Manual
Page Navigation
  315    316    317    318    319  320  321    322    323    324    325  
TM 5-3740-214-14
Table 5-3. Direct and General Support Maintenance Troubleshooting (Continued)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
ENGINE OVERHEATS (Continued)
(2)
Loosen the point gap adjustment screw and place an 0.020 inch (0.52 mm) feeler gage between
the points.
(3)
Tighten the adjusting screw after setting the gap.
(4)
Replace the breaker point cover and go to Step 4e.
e.
Start the engine.
11.
ENGINE BACKFIRES
Step 1.
Check the breaker points.
Figure 5-185. Breaker Point Cover