Table 5-3. Direct and General Support Maintenance Troubleshooting (Continued) -502230300
Table 5-3. Direct and General Support Maintenance Troubleshooting (Continued) -502230302

TM-5-3740-214-14 Aerosol Generator Non-Thermal Insecticide Unltra-Low Volume Model XKA (NSN 374001-076-1341) Manual
Page Navigation
  290    291    292    293    294  295  296    297    298    299    300  
TM 5-3740-214-14
Table 5-3. Direct and General Support Maintenance Troubleshooting (Continued)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
ENGINE OPERATES ERRATICALLY (Continued)
(4)
If the gap is greater than or less than 0.020 inches (0.52 mm), go to Step 5d.
Figure 5-157. Gapping Breaker Points
d.
Reset the breaker point gap.
(1)
Rotate the engine by hand until the breaker points reach their greatest gap.
(2)
Loosen the point gap adjustment screw and place an 0.020 inch (0.52 mm) feeler gage between
the points.
(3)
Tighten the adjusting screw after setting the gap.
(4)
Replace the breaker point cover and go to Step 5e.
e.
Start the engine.
(1)
If the engine starts, the problem is solved.
(2)
If the engine does not start, go to Step 6.
Step 6.
Check the condenser. Use a volt-ohmmeter.