Table 5-3. Direct and General Support Maintenance Troubleshooting (Continued) -502230259
Table 5-3. Direct and General Support Maintenance Troubleshooting (Continued) -502230261

TM-5-3740-214-14 Aerosol Generator Non-Thermal Insecticide Unltra-Low Volume Model XKA (NSN 374001-076-1341) Manual
Page Navigation
  249    250    251    252    253  254  255    256    257    258    259  
TM 5-3740-214-14
Table 5-3. Direct and General Support Maintenance Troubleshooting (Continued)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
ENGINE STOPS SUDDENLY (Continued)
(2)
Remove the valve from the tank.
(3)
Check the valve for plugging or jamming. If the valve is plugged, blow high pressure air through
the valve to unplug it. If the valve is jammed, unjam it.
(4)
If the valve can be repaired, repair it and return it to the tank. Go to Step 8c.
(5)
If the valve cannot be repaired, replace it and go to Step 8c.
c.
Check the fuel line.
(1)
If the fuel line is ok, return it to the valve and carburetor. Go to Step 9.
(2)
If the fuel line is plugged, unplug it and return it to the valve and carburetor. Go to Step 8d.
(3)
If the fuel line is cut or cracked, replace it and go to Step 8d.
d.
Start the engine.
(1)
If the engine starts, the problem is solved.
(2)
If the engine does not start, go to Step 9.
Step 9.
Check the carburetor.
CAUTION
BE CAREFUL not to use force when turning the needle valves in and out. Force can damage the
valves.