Table 5-3. Direct and General Support Maintenance Troubleshooting (Continued) -502230241
Table 5-3. Direct and General Support Maintenance Troubleshooting (Continued) -502230243

TM-5-3740-214-14 Aerosol Generator Non-Thermal Insecticide Unltra-Low Volume Model XKA (NSN 374001-076-1341) Manual
Page Navigation
  231    232    233    234    235  236  237    238    239    240    241  
TM 5-3740-214-14
Table 5-3. Direct and General Support Maintenance Troubleshooting (Continued)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
THE ENGINE IS HARD TO START (Continued)
Figure 5-91. Engine Valve Cover
a. Remove the breather and clean it if necessary.
(1)
Remove the valve cover retaining nut and the valve cover.
(2)
Remove the breather seal and filter. If the filter is dirty and plugged, replace it.
(3)
Remove the gaskets and breather.
(4)
Replace the gaskets and clean all the other parts.
b.
Reassemble the breather assembly and go to Step 8. Make sure the valve cover is securely
tightened to prevent oil leaks.
Step 10.
Check the engine compression.
NOTE
Because automatic compression release engines release compression at 600 rpm, there is a
different compression test procedure for this engine.
5-83






Western Governors University

Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved. Design by Strategico.