Table 5-1. Direct and General Support Preventive Maintenance Checks and Services (Continued) -502230170
Table 5-1. Direct and General Support Preventive Maintenance Checks and Services (Continued) -502230172

TM-5-3740-214-14 Aerosol Generator Non-Thermal Insecticide Unltra-Low Volume Model XKA (NSN 374001-076-1341) Manual
Page Navigation
  160    161    162    163    164  165  166    167    168    169    170  
TM 5-3740-214-14
Table 5-1. Direct and General Support Preventive Maintenance Checks and Services (Continued)
M = Monthly
A/R = As Required
Q = Quarterly
H = Hourly
INTERVAL
ITEM
ITEM TO BE INSPECTED
NO.  M A/R
Q
H
PROCEDURE
3
GOVERNOR
500
Check and reset engine speed. Use a tachometer.
a. Start engine according to engine startup procedures in Chapter 2, Section III.
NOTE
Belts should be installed while checking engine speed.
b. Check operating speed with tachometer. Refer to page 1-6 for correct rpm settings.
Figure 5-13. Governor Assembly
c. Adjust engine speed as necessary.
(1) Loosen bushing nut slightly.
(2) Turn throttle bracket counterclockwise (left) to increase engine speed. Turn it
clockwise (right) to decrease engine speed. Refer to page 1-6 for the correct rating.
CAUTION
DO NOT FORCE bushing nut tight. This could cause binding or stripping
of threads.
(3) When engine speed is adjusted to the correct rpm, tighten bushing nut to lock
throttle bracket.