HOUSING SUBASSEMBLY. - Continued
DUMMY CONNECTOR (DETECTOR POWER CABLE).

M140 Chemical Agent Alarm \(Nsn 6665-01-083-2749\)
Page Navigation
  120    121    122    123    124  125  126    127    128    129    130  
img
. . . . .
ARMY TM 3-6665-329-13&P
AIR FORCE TO 11H2-18-1
3-47 CIRCUIT CARD ASSEMBLY.
This task covers:
a.
Removal.
b.
Installation.
INITIAL SETUP
Tools:
Electronic equipment tool
kit TK-105/G
Troubleshooting references: (para 3-7.3)
Equipment condition: Lid removed during functional testing.
a.
Removal.
(1) Remove lid and panel assembly (para 3-11b steps 1 thru 8).
(2) Remove two screws (1) and Iockwashers (2).
(3) Remove circuit card assembly (3) from connector (4).
b.
Installation.
(1) Install circuit card assembly (3).
(2) Install two screws (1) with Iockwashers (2).
(3) Perform Functional Test (table 3-2).
(4) Install panel assembly (para 3-11c steps 4 thru 8 and 20).
3-104