BATTERY TEST PROCEDURE
Section V. PREPARATION FOR STORAGE OR SHIPMENT

Simulator, Detector Uni Chemical Agent Automatic Alarm, M81 \(Nsn 6665-01-088-4789\)
Page Navigation
  72    73    74    75    76  77  78    79    80    81    82  
img
TM
3-6665-316-12
RECEIVER
TEST
PROCEDURE
4-17.
INITIAL
SETUP
No
special
equipment/materials
required.
Before  performing  the
following  steps,
be
sure
that
the
following
a.
procedures
have
been
performed.
1.
Installation
of
receiver
ring
in
M43A1
Detector
(Paragraph
4-
15b) .
2.
Installation
of
receiver
antenna
(Paragraph
4-14b).
b.
Separate
each
M43A1
Detector,
with
receiver
installed,
from
the
transmitter  by  approximately  20  meters  (66  feet).  The
receiver/detectors
should
be
within
line-of-sight
of
the
transmitter.
Turn  the
Transmitter  CHAN  SEL  switch  to  select
a
channel
matching
c.
the  UNIT
digit  of  the  receiver  to  respond.
Be  sure  the  antenna  is  pointing  straight  up,  the  operating  plate  is
d.
toward  you,  and  you  are  facing  the  receivers.
Switch  to  OPR  and
hold  there  for  5  seconds.  Release  the  switch.
Reset  detector  by  pressing
the  BATTERY
TEST  AND
RESET  PRESS
button.
e.
The  BATTERY  TEST  AND  RESET
PRESS  button
may  have
to  be  held
down  for
60  seconds.
f.
Repeat
Steps
c,
d,
and
e
for
each
of
the
receiver/detectors.
4-34