REPLACEMENT OF TRANSMITTER BATTERIES
REPLACEMENT OF TRANSMITTER BATTERIES - Continued

Simulator, Detector Uni Chemical Agent Automatic Alarm, M81 \(Nsn 6665-01-088-4789\)
Page Navigation
  58    59    60    61    62  63  64    65    66    67    68  
img
TM
3-6665-316-12
REPLACEMENT
OF
TRANSMITTER
BATTERIES
(continued)
4-11.
Removal
a.
1.
Position  transmitter
so
that
slot-head
screw
(1)
holding
cover
(2)
to
chassis  (3)  is  up.
2.
Loosen
screw.
Remove
cover
from
chassis.
3.
Lift  battery  holder  out  of  chassis  until
4.
Locate
battery
holder
(4).
Disconnect
electri-
electrical
connector
(5)
clears
rim
of
chassis.
cal  connector  (5)  from  battery  holder  (4).
6.
Discard
batteries
according
to
Standard
Operating
Procedures.
4-20