Figure D-49. Electrical lead C5-59-218-14.
Figure D-53. Electrical lead C5-59-218-18.

Technical Manual For Decontaminating Apparatus: Power-Driven, Skid-Mounted, 500-Gallon, M12A1
Page Navigation
  467    468    469    470    471  472  473    474    475    476    477  
img
TM 3-4230-209-30&P
D-28
MATERIAL
MATERIAL
PART NO.
PART NO.
DESCRIPTION
QTY
DESCRIPTION
QTY
MM3565 (99974)
WIRE, ELECTRICAL
MM3565 (99974)
WIRE, ELECTRICAL
1
1
1
1
MS25036-112
LUG, TERMINAL
MS25036-112
LUG, TERMINAL
2
I
MS27144-1
1
CONNECTOR, PLUG, ELECTRICAL
1. CUT BULK ELECTRICAL WIRE 5.25 INCHES LONG.
1. CUT BULK ELECTRICAL WIRE 11 INCHES LONG AND STRIP 0.375 INCH
2. STRIP 0.375 INCH INSULATION FROM BOTH ENDS AND CRIMP
I
INSULATION FROM BOTH ENDS.
TERMINAL LUG ON EACH END.
I
2. CRIMP TERMINAL LUG ON ONE END AND ATTACH ELECTRICAL PLUG
3. ALL DIMENSIONS ARE IN INCHES.
CONNECTOR TO OTHER END.
3. ALL DIMENSIONS ARE IN INCHES.
Figure D-52. Electrical lead C5-59-218-17.
Figure D-51. Electrical lead C5-59-218-16.