Outer Ambulatory Airlock Door Assembly Repair.
Figure 3-31. Outer Ambulatory Airlock Door Assembly Repair

TM-10-5410-228-24 Chemical Biologiocal Protective Shelter (CBPS) System NSN 5410-01-441-8054 (Green) (EIC:5ZT) NSN 5410-01-482-4633 (Tan) Manual
Page Navigation
  558    559    560    561    562  563  564    565    566    567    568  
TM 10-5410-228-24
3.10.4 Outer Ambulatory Airlock Door Assembly Repair Continued.
(10) Remove four screws (23), four flat washers (24), four lockwashers (25) and four nuts (26)
securing door catch (27) and door catch spacer (28) to outer ambulatory frame assembly (2).
Discard four lockwashers (25).
b. Assembly (Refer to Figure 3-31)
Adhesives and cleaners are flammable and give off harmful vapors. Use adhesive and cleaner
sparingly and only in well ventilated area. Avoid prolonged breathing of vapors. Keep away
from heat, sparks, open flames. Wear gloves when handling adhesive and cleaner.
NOTE
Apply new gasket to clean, dry surface only.
(1)
Clean adhesive residue from door assembly (7) with rag dampened with alcohol. Allow door
assembly (7) to dry completely before applying new gasket.
(2)
Cut new rubber door gasket (15) to length and secure to door assembly (7) with adhesive (Item
7, Appx C).
(3)
Install window assembly (14) in door assembly (7) (reference TM 10-5410-228-10).
(4)
Secure handle (13) to door assembly (7) with two screws (12).
(5)
Secure handle (11) to door assembly (7) with two screws (10) with adhesive (Item 9, Appx C).
(6)
Secure striker plate (9) to door assembly (7) with screw (8).
(7)
Secure two hinges (6) to door assembly (7) with six screws (3), six flat washers (4), and six new
self-locking nuts (5) (Item 44, Appx E).
(8)
Secure door catch (17) and door catch spacer (28) to outer ambulatory frame assembly (2) with
four screws (23), four flat washers (24), four new lockwashers (25) (Item 24, Appx E) and four
nuts (26).
(9)
Apply adhesive (Item 8, Appx C) to fourteen screws (21) and secure seven spring clips (22) to
outer ambulatory frame assembly (2).
(10) Place door assembly (7) in outer ambulatory frame assembly (2). Secure two hinges (6) and four
hinge spacers (19 and 20) to outer ambulatory frame assembly (2) with six screws (16), six flat
washers (17), six new self-locking nuts (18) (Item 31, Appx E).
(11) Cut fastener hook (1) to length, remove protective tape backing and press onto outer ambulatory
frame assembly (2).
c.
Repair (Refer to Figure 3-31)
See para 3.10.1 for repair of holes, cuts, or tears in fabric of outer ambulatory airlock door assembly.
3-164