• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 3-30. Inner Ambulatory Airlock Door Assembly Repair
Assembly -812530588

TM-10-5410-228-24 Chemical Biologiocal Protective Shelter (CBPS) System NSN 5410-01-441-8054 (Green) (EIC:5ZT) NSN 5410-01-482-4633 (Tan) Manual
Page Navigation
  557    558    559    560    561  562  563    564    565    566    567  
TM 10-5410-228-24
3.10.4 Outer Ambulatory Airlock Door Assembly Repair.
This task covers:
a. Disassembly
c. Repair
b. Assembly
INITIAL SETUP
Equipment Conditions:
Tools/Test Equipment:
Shop Equipment, Automotive Maintenance and
Ambulatory airlock door assemblies removed
Repair (Item 38, Appendix B)
(reference TM 10-5410-228-10).
Spare Parts Kit (TM 10-5410-228-10)
References:
TM 10-5410-228-10
Materials/Parts:
Isopropyl Alcohol (Item 12, Appendix C)
Rubber Gloves (Item 25, Appendix C)
Materials/Parts: (Cont.)
Wiping Rags (Item 39, Appendix C)
Coated Fabric Gasket (55926) STYLE 11265
Adhesive (Item 7, Appendix C)
Gasket (Clean Seal Inc.) CS 109 HR-1
Thread Locking Adhesive (Item 8, Appendix C)
Fastener Hook and Fastener Loop Gasket (11153)
Four Lockwashers (Item 24, Appendix E)
173098
Twelve Self-locking Nuts (Item 44, Appendix E)
a. Disassembly (Refer to Figure 3-31)
NOTE
Remove/disassemble only to the extent necessary to remove or replace defective
assemblies/components. Use standard maintenance shop practices/procedures.
Fastener hook should only be replaced if damaged.
(1)
Remove fastener hook and fastener loop door frame gasket (1) from outer ambulatory frame
assembly (2), and clean gasket adhesive residue from surface of outer ambulatory frame
assembly (2) with rag dampened with alcohol. Discard gasket (1).
(2)
Remove six screws (3), six flat washers (4), and six self-locking nuts (5) securing two hinges (6)
to door assembly (7). Discard six self-locking nuts (5). Separate door assembly (7) from outer
ambulatory frame assembly (2).
(3)
Remove screw (8) securing striker plate (9) to door assembly (7).
(4)
Remove two screws (10) securing handle (11) to door assembly (7).
(5)
Remove two screws (12) securing handle (13) to door assembly (7).
(6)
Remove window assembly (14) from door assembly (7) (reference TM 10-5410-228-10).
NOTE
Rubber door gasket should only be replaced if damaged.
(7)
Remove rubber door gasket (15) from door assembly (7). Clean gasket adhesive residue from
surface of door assembly (7) with rag dampened in isopropyl alcohol. Discard rubber door gasket
(15).
(8)
Remove six screws (16), six flat washers (17), six self-locking nuts (18) and four hinge spacers
(19 and 20) securing two hinges (6) to outer ambulatory frame assembly (2). Discard six self-
locking nuts (18).
(9)
Remove fourteen screws (21) securing seven spring clips (22) to outer ambulatory frame
assembly (2).
3-163