Assembly -812530584
Figure 3-30. Inner Ambulatory Airlock Door Assembly Repair

TM-10-5410-228-24 Chemical Biologiocal Protective Shelter (CBPS) System NSN 5410-01-441-8054 (Green) (EIC:5ZT) NSN 5410-01-482-4633 (Tan) Manual
Page Navigation
  555    556    557    558    559  560  561    562    563    564    565  
TM 10-5410-228-24
(10) Apply adhesive (Item 8, Appx C) to four screws (15). Secure timer mounting plate (17) to door
assembly (7) with four screws (14), four new lockwashers (15) (Item 31, Appx E) and four flat
washers (16).
(11) Secure handle (13) to door assembly (7) with two screws (12).
(12) Secure handle (11) to door assembly (7) with two screws (10) with adhesive (Item 7, Appx C).
(13) Secure striker plate (9) to door assembly (7) with screw (8).
(14) Place door assembly (7) in inner ambulatory frame assembly (2). Secure two hinges (6) to door
assembly (7) with six screws (3), six flat washers (4), and six new self-locking nuts (5) (Item 44,
Appx E).
(15) Cut new fastener hook (1) to length, remove protective tape backing and press onto inner
ambulatory frame assembly (2).
c.
Repair (Refer to Figure 3-30)
See para 3.10.1 for repair of holes, cuts, or tears in fabric of inner ambulatory airlock door assembly.
3-161