(55) Lubricate O-ring (25) with a light coating of hydraulic fluid.
(56) Install connector (23) on hydraulic manifold (3), finger tight.
(57) Torque connector (23) to 190 10 in.-lb (16 1 ft-lb).
(58) Install new O-ring (24) (Item 61, Appx E) on connector (23). Ensure O-ring (24) is seated and
retained properly.
(59) Lubricate O-ring (24) with a light coating of hydraulic fluid.
(60) Install tube assembly (22) on connector (23), finger tight.
(61) Torque tube assembly (22) to 220 10 in.-lb (18 1 ft-lb).
(62) Unplug port on hydraulic manifold (3) and end of tube assembly (26).
(63) Check sealing surfaces on elbow (27) for damage or material build up. If required, replace elbow
(27) or clean any material build up with clean, lint-free cloth.
(64) Install new O-ring (29) (Item 50, Appx E) on elbow (27). Ensure O-ring (29) is seated and
retained properly.
(65) Lubricate O-ring (29) with a light coating of hydraulic fluid.
(66) Install elbow (27) on hydraulic manifold (3), finger tight.
(67) Torque elbow (27) to 190 10 in.-lb (16 1 ft-lb).
(68) Install new O-ring (28) (Item 61, Appx E) on elbow (27). Ensure O-ring (28) is seated and
retained properly.
(69) Lubricate O-ring (28) with a light coating of hydraulic fluid.
(70) Install tube assembly (26) on elbow (27), finger tight.
(71) Torque tube assembly (26) to 220 10 in.-lb (18 1 ft-lb).
(72) Unplug port on hydraulic manifold (3) and end of tube assembly (30).
(73) Check sealing surfaces on connector (31) for damage or material build up. If required, replace
connector (31) or clean any material build up with clean, lint-free cloth.
(74) Install new O-ring (33) (Item 57, Appx E) on connector (31). Ensure O-ring (33) is seated and
retained properly.
(75) Lubricate O-ring (33) with a light coating of hydraulic fluid.
(76) Install connector (31) on hydraulic manifold (3), finger tight.
(77) Torque connector (31) to 780 25 in.-lb (60 2 ft-lb).
(78) Install new O-ring (32) (Item 63, Appx E) on connector (31). Ensure O-ring (32) is seated and
retained properly.
(79) Lubricate O-ring (32) with a light coating of hydraulic fluid.
(80) Install tube assembly (30) on connector (31), finger tight.
(81) Torque tube assembly (30) to 480 25 in.-lb (40 2 ft-lb).