Filter/Drier Components and Valves Replacement.
Figure 3-18. Filter/Drier Components and Valves Replacement

TM-10-5410-228-24 Chemical Biologiocal Protective Shelter (CBPS) System NSN 5410-01-441-8054 (Green) (EIC:5ZT) NSN 5410-01-482-4633 (Tan) Manual
Page Navigation
  491    492    493    494    495  496  497    498    499    500    501  
TM 10-5410-228-24
a. Removal (Refer to Figure 3-18)
(1)
Disconnect cable assembly 1A4A1W3 connector P17 (1) from actuator RSV3 (2) on top of tube
assembly (3).
(2)
Remove actuator RSV3 (2) from tube assembly (3).
(3)
Loosen screw (4) on hose clamp (5) and remove hose clamp (5) securing filter/drier (6) to drier
bracket (7).
(4)
Using two wrenches, disconnect filter/drier (6) from tube assembly (3).
Removal and brazing of refrigerant tube assemblies shall be in accordance with safety
requirements. All safety requirements applicable to brazing of tubes shall be observed.
(5)
Remove two screws (8), two lockwashers (9) and two flat washers (10) securing tube assembly
(3) to valve support bracket (11). Discard two lockwashers (9).
(6)
Remove two nuts (12), two lockwashers (13), four flat washers (14) and two screws (15) securing
valve support bracket (11) to inside passenger side of ECU (16). Discard two lockwashers (13).
(7)
Remove two nuts (17), two lockwashers (18), four flat washers (19) and two screws (20) securing
drier bracket (7) to inside structure of ECU (16). Discard two lockwashers (18).
b. Installation (Refer to Figure 3-18)
(1)
Secure drier bracket (7) to inside structure of ECU (16) with two screws (20), four flat washers
(19), two new lockwashers (18) (Item 18, Appx E) and two nuts (17).
(2)
Secure valve support bracket (11) to inside passenger side of ECU (16). Secure two screws (15),
four flat washers (14), two new lockwashers (13) (Item 17, Appx E) and two nuts (12).
(3)
Secure tube assembly (3) to valve support bracket (11) with two screws (8), two new lockwashers
(9) (Item 16, Appx E) and two flat washers (10).
(4)
Using two wrenches, connect filter/drier (5) to tube assembly (3).
(5)
Secure filter/drier (6) to drier bracket (7) with hose clamp (5) and tighten screw (4) on hose
clamp (5).
(6)
Install actuator RSV3 (2) onto liquid line solenoid valve (3).
(7)
Connect cable assembly 1A4A1W3 connector P17 (1) to actuator RSV3 (2) on top of tube
assembly (3).
3-97