Prime Hydraulic Pump
Figure 3-2. Auxiliary Power Pack (Sheet 2 of 2)

TM-10-5410-228-24 Chemical Biologiocal Protective Shelter (CBPS) System NSN 5410-01-441-8054 (Green) (EIC:5ZT) NSN 5410-01-482-4633 (Tan) Manual
Page Navigation
  414    415    416    417    418  419  420    421    422    423    424  
TM 10-5410-228-24
3.7.1
Auxiliary Power Pack Replacement Continued.
NOTE
Ensure that hydraulic reservoir has the correct amount of hydraulic fluid. Fluid level on the
hydraulic reservoir level gage should be between the HOT and COLD marks.
(2)  Gain access to the ECU hydraulic manifold and disconnect connector on solenoid/valve SV2 per
para 2.14.4.
(3)  Manually open solenoid/valve SV2.
(4)  Ensure that ESS is in the OFF position.
(5)  Turn POWER MODE selector switch on the rear control panel to EXT position.
(6)  Quickly push NBC FAN switch/indicator ON and OFF a couple of times. Listen to the sound of
the pump and observe if the NBC fan is rotating. Loud noise indicates pump is not primed yet.
Repeat this step several times until the fan turns.
(7)  Reconnect connector on solenoid/valve SV2.
(8)  Refer to para 2.14.5e. to adjust auxiliary power pump.
Figure 3-2. Auxiliary Power Pack (Sheet 1 of 2)
3-20
Change 1