Figure 2-68. Plastic Tubing Replacement
Axial Fan Impeller Replacement.

TM-10-5410-228-24 Chemical Biologiocal Protective Shelter (CBPS) System NSN 5410-01-441-8054 (Green) (EIC:5ZT) NSN 5410-01-482-4633 (Tan) Manual
Page Navigation
  387    388    389    390    391  392  393    394    395    396    397  
TM 10-5410-228-24
2.17 RECIRCULATION FILTER.
2.17.1 Filter Element Replacement.
This task covers:
a. Removal
b. Installation
INITIAL SETUP
Tools/Test Equipment:
Shop Equipment, Automotive Maintenance and
Repair (Item 38, Appendix B)
a. Removal (Figure 2-69)
Ensure that recirculation filter is disconnected from power source before performing
maintenance procedure. Electric shock can cause serious injury or death.
NOTE
Change filter in recirculation filter prior to every mission.
(1)
Disconnect recirculation filter unit (1) from power source.
(2)
Unlatch four link-lock fasteners (2) from cover (3).
(3)
Remove cover (3) and filter element (4).
b. Installation (Figure 2-69)
(1)
Install new filter element (4) with metal hem (5) facing downward.
(2)
Replace cover (3).
(3)
Latch four link-lock fasteners (2).
3
4
5
2
1
Figure 2-69. Recirculation Filter-Filter Element Replacement