Inflation Manifold Replacement.
Figure 2-66. Inflation Manifold Replacement

TM-10-5410-228-24 Chemical Biologiocal Protective Shelter (CBPS) System NSN 5410-01-441-8054 (Green) (EIC:5ZT) NSN 5410-01-482-4633 (Tan) Manual
Page Navigation
  381    382    383    384    385  386  387    388    389    390    391  
TM 10-5410-228-24
b. Repair (Refer to Figure 2-66)
(1)
Hose repair or replacement may be accomplished by cutting hose at barb end of adapters and
elbows, then removing hose.
(2)
Cut new hose to required length.
Adhesives, sealants, solvents and cleaners are flammable and give off harmful vapors. Use
adhesives, sealants, solvents and cleaners sparingly and only in well ventilated area. Avoid
prolonged breathing of vapors. Keep away from heat, sparks, open flames. Wear gloves and
goggles when handling adhesives, sealants, solvents and cleaners.
(3)
Ensure old adhesive and sealant has been removed from barbs.
(4)
Apply adhesive to barbs.
(5)
Install hose onto barbs.
c.
Assembly (Refer to Figure 2-66)
NOTE
Sealant is in ABS repair kit.
(1)
Apply sealant to threads on hose assembly (7). Install hose assembly (7) on large end of straight
check valve with shutoff (5).
(2)
Slide hose assembly (7) through hole in ambulatory airlock.
(3)
Apply adhesive to barb end of elbow in air beam input port (8).
(4)
Install hose assembly (7) on elbow in air beam input port (8).
(5)
In six places, apply sealant and install hose assemblies (6) to tee check valve with shutoff (4).
(6)
Apply sealant and install shelter to airbeam hose assembly (2) to tee check valve with shutoff
(4).
(7)
Apply sealant and install shelter to airbeam hose assembly (2) to vehicle air flow bulkhead
fitting (3).
2-323