Receptacle Panel Repair.
Figure 2-53. Receptacle Panel Repair

TM-10-5410-228-24 Chemical Biologiocal Protective Shelter (CBPS) System NSN 5410-01-441-8054 (Green) (EIC:5ZT) NSN 5410-01-482-4633 (Tan) Manual
Page Navigation
  334    335    336    337    338  339  340    341    342    343    344  
TM 10-5410-228-24
2.13.31 Receptacle Panel Repair Continued.
b. Assembly (Refer to Figure 2-53)
(1)
Install utility outlet cable assembly (21) in strain relief (22).
(2)
Secure six receptacle connectors (14) and six gaskets (19) to receptacle panel (4) with 24 screws
(15), 24 flat washers (16), 24 new lockwashers (17) (Item 14, Appx E) and 24 nuts (18).
(3)
If required, cut damaged terminal lug(s) (12) from wires and crimp new terminal lug(s) (12) to
wire. Remove tags from wires.
(4)
Secure 26 terminal lugs (12) and five terminal lugs (13) to six receptacle connectors (14) with
eighteen screws (10) and 36 flat washers (11).
(5)
Install tie-down straps as required.
(6)
Secure receptacle panel (4) to pan (9) with six screws (6), six new lockwashers (7) (Item 17, Appx
E) and six flat washers (8).
(7)
Install six caps (20) on six receptacle connectors (14).
NOTE
Secure six cap lanyards under six screws when securing receptacle panel to exterior frame.
(8)
Secure receptacle panel (4) to exterior frame (5) with twenty screws (1), twenty new lockwashers
(2) (Item 17, Appx E) and twenty flat washers (3).