LEFT/RIGHT MAP LIGHT ON FORWARD CONTROL PANEL DOES NOT COME ON.
LEFT/RIGHT MAP LIGHT ON FORWARD CONTROL PANEL DOES NOT COME ON Continued. -812530183

TM-10-5410-228-24 Chemical Biologiocal Protective Shelter (CBPS) System NSN 5410-01-441-8054 (Green) (EIC:5ZT) NSN 5410-01-482-4633 (Tan) Manual
Page Navigation
  154    155    156    157    158  159  160    161    162    163    164  
TM 10-5410-228-24
2.8
UNIT LEVEL TROUBLESHOOTING PROCEDURES Continued.
27. LEFT/RIGHT MAP LIGHT ON FORWARD CONTROL PANEL DOES NOT COME ON Continued.
1
Turn system off.
Gain access to circuit breaker CB4 (see
Yes
Does continuity exist?
para 2.13.23).
Set CB4 to ON.
Test for continuity between terminals.
No
Notify direct support to
repair cable assembly
1A4W7.
Gain access to pan assembly (see
para 2.13.25).
Yes
Do a continuity check of the
Does continuity exist?
electrical wiring per Appendix F,
Fig. F-9, sheet 1.
Repair wiring as required.
No
Replace circuit breaker
CB4.
2-96