NO AIR FLOW WHEN MISSION PROFILE SWITCH IS SET FOR MOBILE MODE cont'd -812530174
NO AIR FLOW WHEN MISSION PROFILE SWITCH IS SET FOR MOBILE MODE cont'd -812530176

TM-10-5410-228-24 Chemical Biologiocal Protective Shelter (CBPS) System NSN 5410-01-441-8054 (Green) (EIC:5ZT) NSN 5410-01-482-4633 (Tan) Manual
Page Navigation
  147    148    149    150    151  152  153    154    155    156    157  
TM 10-5410-228-24
25. NO AIR FLOW WHEN MISSION PROFILE SWITCH IS SET FOR MOBILE MODE, `MOBILE'
INDICATOR OFF, AND ESS MODE SWITCH ON, INTERNAL POWER MODE Continued.
4
Check for continuity between
Does
pin to pin on connector J1 of
Yes
continuity
cable assembly 1A4A1W1 per
exist?
Appendix F, Fig. F-4, sheet 2.
No
Does
Notify direct
Yes
continuity
support to repair
exist?
cable assembly
1A4A1W1.
No
Remove cable assembly 1A4W6
connector P2 from J2.
Test for continuity of cable per
Fig. 3-5, sheet 4.
Does
No
Yes
Check for continuity
continuity
between pin to pin on
exist?
connector P2 of cable
assembly 1A4W6.
Does
Notify direct support to
Yes
continuity
repair cable assembly
exist?
1A4W6.
No
Do a continuity check of the
electrical wiring per Appendix
F, Fig. F-9, sheet 4.
2-89