NO AIR FLOW WHEN MISSION PROFILE SWITCH IS SET FOR STATIC MODE cont'd -812530124
NBC FAN `PRESSURE LOW' INDICATOR DOES NOT COME ON cont'd -812530126

TM-10-5410-228-24 Chemical Biologiocal Protective Shelter (CBPS) System NSN 5410-01-441-8054 (Green) (EIC:5ZT) NSN 5410-01-482-4633 (Tan) Manual
Page Navigation
  97    98    99    100    101  102  103    104    105    106    107  
TM 10-5410-228-24
8.
NBC FAN `PRESSURE LOW' INDICATOR DOES NOT COME ON AND AUDIBLE ALARM DOES
NOT SOUND WHEN NBC FAN SWITCH IS FIRST TURNED ON MUTE SWITCH OFF, `NBC FAN
ON' INDICATOR ON.
Press ALARM MUTE switch.
Observe ALARM MUTE indicator.
No
Is indicator on (blue)?
Yes
Turn ECV OFF.
Tag power panel and cab area.
Gain access to cover assembly
components (see para 2.13.23).
Remove connector from NBC
SHELTER PRESSURE gauge.
Test for continuity between pins H and J
on gauge.
No
Replace NBC SHELTER
Does continuity exist?
PRESSURE gauge.
Yes
2
1
A
B
J
K
H
C
F
D
E
REAR VIEW OF GAUGE
2-39