NO AIR FLOW WHEN MISSION PROFILE SWITCH IS SET FOR STATIC MODE cont'd -812530118
NO AIR FLOW WHEN MISSION PROFILE SWITCH IS SET FOR STATIC MODE cont'd

TM-10-5410-228-24 Chemical Biologiocal Protective Shelter (CBPS) System NSN 5410-01-441-8054 (Green) (EIC:5ZT) NSN 5410-01-482-4633 (Tan) Manual
Page Navigation
  91    92    93    94    95  96  97    98    99    100    101  
TM 10-5410-228-24
6.
NO AIR FLOW WHEN MISSION PROFILE SWITCH IS SET FOR STATIC MODE INTERNAL
POWER `STATIC' INDICATOR ON Continued.
1
Shut off power to system.
Remove connector plugs from SV2 and SV9
(see para 2.14.4).
Remove connector 1A4A1W3P1.
Check continuity of cable per Appendix F,
Fig. F-4, sheet 1 P1-U to P13-A, P1-W to
P13-B, P1-a to P14-A, & P1-b to P14-B.
Gain access to cable assembly
1A4A1W1.
Does
Yes
Test for continuity per Appendix
continuity
F, Fig. F-4, sheet 2 J1-U to J3-U,
exist?
J1-W to J3-W, J1-a to J3-a, & J1-b
to J3-b.
No
Does
Repair or replace
No
continuity
cable assembly
Notify direct support
exist?
1A4A1W1.
to repair cable
assembly 1A4A1W3.
Yes
Gain access to cable assembly
1A4W6.
Test for continuity per Fig 3-5 sheet
4, P1-a to P2-a, P1-b to P2-b, P1-u
to P2-u & P1-w to P2-w.
Does
Notify direct support to
No
continuity
repair cable assembly
exist?
1A4W6.
Yes
Gain access to inside of control panel (paras
2.13.23 and 2.13.25).
Do a continuity check of the electrical wiring
per Appendix F, Fig. F-9, sheet 6 A4J2-U to
A4S8-4, J2-W to A4TBGND, J2-b to
A4TBGND, & J2-a to A4S1B-9.
Repair wiring as required.
2-33