3.
INVERTER INDICATOR LIGHTS ON, NO VOLTAGE TO OUTLETS Continued.
Inverter EXTENDED INPUT RANGE indicator
(18 to 22 Vdc, 29 to 32 Vdc).
Measure supply voltage to
inverter.
Is supply
Is supply
voltage between
No
voltage greater
No
Replace inverter (see
18 and 22 Vdc or
than 32 Vdc or less
para 2.13.21).
between 29
than 18
and 32
Vdc?
Vdc?
Yes
Yes
Extended range operating.
Supply voltage out of range.
Check ECV battery charging
Check ECV battery charging
system (see TM 9-2320-387-
system (see TM 9-2320-387-
24-1).
24-1).