Figure 1-21. Mobile Mode, Internal Power, Vent Mode, Full NBC
Figure 1-23. Mobile Mode, Internal Power, Cool Mode, Thermostat Open, Full NBC

TM-10-5410-228-24 Chemical Biologiocal Protective Shelter (CBPS) System NSN 5410-01-441-8054 (Green) (EIC:5ZT) NSN 5410-01-482-4633 (Tan) Manual
Page Navigation
  48    49    50    51    52  53  54    55    56    57    58  
TM 10-5410-228-24
1.16.14 Mobile Mode, Internal Power, Cool Mode, Full NBC.
In mobile mode, solenoid valve SV1 is energized (open) which forces the hydraulic fluid through flow control,
FP1. The same conditions exist in this configuration as exist in the Mobile Mode, vent mode (figure 1-21)
except that solenoid valve SV4 is energized (open) allowing the compressor motor, M1A, to operate.
Valve
SV1
SV2
SV4
SV5
SV6
SV7
SV8
SV9
Energized State
ON
OFF
ON
OFF
OFF
OFF
OFF
ON
Position
Open
Closed
Open
Closed
Closed
Open
Closed
Closed
Figure 1-22. Mobile Mode, Internal Power, Cool Mode, Full NBC